Industrial Lightning Protection & Electrical Safety Solutions
Call: +91 99906 45119   |   WhatsApp
SN ENGINEERING · B2B LIGHTNING PROTECTION

Lightning Protection Systems for Industrial & Infrastructure Projects

Technical B2B ESE lightning arrester solutions featuring Tercel and LEESAS Stormflash models for project enquiry, model comparison and quotation support.

Explore Product Range

Why Lightning Protection Is Necessary

Lightning can create high-current electrical and thermal effects that may damage structures, electrical systems and equipment, and may create dangerous potential differences. A properly engineered lightning protection system uses coordinated air termination, down conductor, bonding, earth termination and surge protection measures to provide defined paths for lightning current and reduce risk to the protected structure and its systems.

ESE Lightning Arrester

Early Streamer Emission (ESE) lightning arrester solutions for industrial, commercial and infrastructure project enquiries.

B2B PROJECT ENQUIRY

ESE Lightning Arrester

Early Streamer Emission air terminal solution for project enquiries where ESE technology is specified and accepted by the project consultant or authority.

Typical applications:
Industrial plants, warehouses, commercial facilities, institutional campuses and infrastructure projects.
WhatsApp Quote

Tercel ESE Lightning Arrester Series

Tercel Early Streamer Emission (ESE) lightning arrester models for industrial, commercial and infrastructure project enquiries.

ESE LIGHTNING PROTECTION

Tercel Lightning Protection – ANS Model

Tercel ANS model Early Streamer Emission (ESE) lightning protection air terminal for industrial, commercial and infrastructure project enquiries.

Brand: Tercel Lightning Protection
Model: ANS
Category: ESE Lightning Arrester
Technical data: As per approved Tercel ANS catalogue / test documentation
WhatsApp Quote
ESE LIGHTNING PROTECTION

Tercel TZ 20 ESE Lightning Arrester

ESE lightning protection product for project-specific applications.

Model: TZ 20
Category: ESE Lightning Arrester
WhatsApp Quote
ESE LIGHTNING PROTECTION

Tercel TZ 40 ESE Lightning Arrester

ESE lightning arrester for industrial and infrastructure projects.

Model: TZ 40
Category: ESE Lightning Arrester
WhatsApp Quote
ESE LIGHTNING PROTECTION

Tercel TZ 50 ESE Lightning Arrester

Tercel ESE lightning protection solution for engineered projects.

Model: TZ 50
Category: ESE Lightning Arrester
WhatsApp Quote
ESE LIGHTNING PROTECTION

Tercel TZ 63 ESE Lightning Arrester

ESE lightning protection system for industrial applications.

Model: TZ 63
Category: ESE Lightning Arrester
WhatsApp Quote
ESE LIGHTNING PROTECTION

Tercel TZ 90 ESE Lightning Arrester

Tercel ESE lightning protection product for project requirements.

Model: TZ 90
Category: ESE Lightning Arrester
WhatsApp Quote
Model-specific technical data: For Tercel TZ-series model selection, protection radius, triggering time advance, installation height and Lightning Protection Level should be verified against the applicable product technical sheet and project specification before final quotation.

LEESAS Stormflash ESE Lightning Protection – Technical Models

LEESAS Stormflash Early Streamer Emission (ESE) air terminal technical data for B2B project review, consultant comparison, BOQ preparation and quotation enquiries. Protection radius depends on the Stormflash model efficiency (ΔT), installation height and selected Lightning Protection Level.

MODEL

LEESAS STORMFLASH 15

ΔT 15 μs
Technical Parameter Specification
Brand / SeriesLEESAS ENERTECH – Stormflash
TypeEarly Streamer Emission (ESE) Air Terminal
Triggering Time Advance (ΔT)15 μs
Applicable StandardNF C 17-102:2011 / UNE 21186:2011
Material304L Stainless Steel (Inox)
External Power SupplyNot Required
BatteryNot Required
Down Conductor CompatibilityTape/Strip, Round Conductor, Isolated/Insulated Cables/HVSC Cable etc.
Warranty20 years

STORMFLASH 15 – Protection Radius as per NF C 17-102 (2011)

Mast Height (m) Level I Level II Level III Level IV
213 m15 m18 m20 m
319 m22 m27 m31 m
425 m30 m36 m41 m
532 m37 m45 m51 m
632 m38 m46 m52 m
833 m39 m47 m54 m
1034 m40 m49 m56 m
2035 m44 m55 m63 m
3035 m44 m58 m69 m
4035 m44 m60 m72 m
MODEL

LEESAS STORMFLASH 60

ΔT 60 μs
Technical Parameter Specification
Brand / SeriesLEESAS ENERTECH – Stormflash
TypeEarly Streamer Emission (ESE) Air Terminal
Triggering Time Advance (ΔT)60 μs
Applicable StandardNF C 17-102:2011 / UNE 21186:2011
Impulse Current Test70 kA (8/20 μs) – CPRI (Government of India) tested
Material304L Stainless Steel (Inox)
External Power SupplyNot Required
BatteryNot Required
Down Conductor CompatibilityTape/Strip, Round Conductor, Isolated/Insulated Cables/HVSC Cable etc.
Warranty20 years

STORMFLASH 60 – Protection Radius as per NF C 17-102 (2011)

Mast Height (m) Level I Level II Level III Level IV
231 m35 m39 m43 m
347 m52 m58 m63 m
463 m69 m78 m85 m
579 m86 m97 m107 m
679 m87 m97 m107 m
879 m88 m98 m108 m
1079 m88 m99 m109 m
1580 m89 m101 m111 m
2080 m89 m102 m113 m
4580 m89 m105 m119 m
5080 m89 m105 m120 m
8080 m89 m105 m120 m
10080 m89 m105 m120 m
Technical Note: For LEESAS Stormflash, the protection radius (Rp) is calculated according to NF C 17-102 (edition 2011) and depends on Stormflash efficiency (ΔT), installation height and selected Lightning Protection Level (LPL I, II, III or IV). The catalogue also states that risk assessment shall be calculated according to NF C 17-102 (edition 2011) / IEC 62305-2. Final project selection should follow the applicable project specification and accepted design basis.

Typical Applications

Lightning protection solutions may be required across many types of industrial, commercial and infrastructure facilities.

Factories & Manufacturing Plants

Protection for industrial buildings, process areas, utilities, warehouses and electrical infrastructure.

Data Centres & Critical IT

External lightning protection coordinated with grounding, bonding and surge protection measures.

Hospitals & Institutions

Protection requirements for healthcare, educational and institutional buildings and equipment systems.

Warehouses & Logistics

Large roof-area protection, down conductor routing and grounding arrangements.

Commercial Buildings

Lightning protection for offices, mixed-use buildings, hotels and other commercial facilities.

Solar & Renewable Projects

Protection coordination for solar installations, equipment areas and associated electrical infrastructure.

Airports & Infrastructure

Project-specific protection systems for infrastructure, transport, terminals and utility facilities.

Industrial Campuses

Multi-building lightning protection, bonding, grounding and maintenance requirements.

Testing, Documentation & Project Approvals

B2B and tender projects may require technical data, test reports, drawings, calculations and project-specific approvals.

Technical Data Sheets

Product model, material, dimensions, installation information and other relevant technical parameters.

Test Reports

Project teams may require applicable test reports for the specific offered model or component.

Layout & BOQ Review

Building geometry, installation height and required protection coverage should be reviewed against the selected ESE model and project requirements.

Consultant / Tender Compliance

Required approvals and compliance documentation vary by project, authority and tender specification.

Important: SN Engineering should only claim a specific approval, certification or test report when it is actually applicable and available for the offered product or project. Brand-specific approvals should not be generalized to unrelated products.

Frequently Asked Questions

Quick guidance for project buyers, consultants and contractors.

Why is lightning protection necessary?

It helps intercept lightning, provide defined current paths, manage potential differences through bonding, and coordinate grounding and surge protection measures to reduce risk to structures and systems.

What details are needed for quotation?

Share building length, width, height, roof layout, site location, required system type, BOQ, tender specification and required documentation.

Can I send a direct product enquiry?

Yes. Use the WhatsApp Quote button or Inquiry Form on this page and provide product, quantity, application and project location.

Need Lightning Protection Selection or a Project Quote?

Share building dimensions, project location, required system type, BOQ and consultant specification.

WhatsApp Quote